KNOWLEDGE / BATTERY TESTING The short answer Internal resistance is a condition-dependent measurement, not one permanent cell constant. Compare like-for-like tests before comparing milliohms. Hero: CurrentCells original explanatory diagram. Qualitative test-method comparison, not measured cell data. Two battery specifications can report different internal resistance values without either measurement being wrong. One supplier may use a small alternating signal at 1,000 hertz. Another may calculate the voltage drop after a ten-second discharge pulse. Both numbers are expressed in milliohms, but they do not capture the same response. Comparing them without the test conditions can turn a procurement spreadsheet into a misleading ranking. Internal resistance matters because it helps explain voltage sag, power limits and part of the heat generated during operation. It does not, by itself, tell you how many kilowatt-hours remain in a battery or whether a pack is safe. The useful question is not simply which cell has the lowest resistance. It is which measurement describes the job the battery must perform. 1. A battery is not a fixed resistor A resistor on a circuit board is a useful starting point: current through resistance produces a voltage difference. A battery adds electrochemistry. Electrons travel through conductive components while ions move through electrolyte and electrode materials. Reactions at interfaces and transport within the cell respond on different timescales. The measured voltage therefore changes immediately when a load is applied and continues changing while that load remains. A peer-reviewed study by Anup Barai and colleagues , published in Scientific Reports in 2018, examined precisely this measurement-timescale problem. It explains why state of charge, temperature, health, current amplitude and test duration all matter when characterizing lithium-ion cell resistance. Its enduring lesson is methodological, not a claim that every modern cell behaves like the cells in that experiment. For a short pulse, an effective resistance can be calculated from the change in voltage divided by the change in current. The word effective matters. As the sampling point moves later in the pulse, the result includes more of the time-dependent electrochemical response. A ten-second value should not be casually relabeled as the cell’s purely ohmic resistance. This also explains why milliohms need context. A low number measured at a warm temperature and a favorable charge level is not a guarantee of the same performance on a cold morning near the bottom of the operating window. Battery management systems work with operating limits and models, not one universal resistance constant. 2. DCIR, ACIR and EIS measure different views Direct-current internal resistance, usually shortened to DCIR, is commonly derived from a controlled current step or pulse. The test records voltage and current before and during the change. The protocol must specify the pulse length and the exact time at which voltage is sampled. Discharge and charge pulses can produce different results, so direction belongs in the specification too. Alternating-current internal resistance, or ACIR, is commonly measured using a small AC signal at a stated frequency, often 1 kHz. Because voltage and current can be out of phase, the underlying measurement is impedance, a frequency-dependent quantity with real and imaginary components. A reported resistance may be the real component; an instrument can also report impedance magnitude. Buyers need to know which quantity appears in the data sheet. Electrochemical impedance spectroscopy, or EIS, sweeps across frequencies instead of reporting only one point. That can help distinguish contributions associated with different processes when combined with an appropriate model. It is not a magic decoder. Test setup, cell stability, interpretation and the choice of equivalent circuit still affect what can be concluded. BatteryDesign.net’s DCIR/ACIR guide is a useful introduction to pulse and frequency methods. Battery University likewise shows why AC and DC results can differ for the same battery. Neither is a reason to apply a universal conversion factor between ACIR and DCIR. A ratio observed for one chemistry, cell format or protocol is not a general law. The practical division is straightforward: use a repeatable method for manufacturing comparisons, and use application-relevant testing to establish power capability. A convenient production screening measurement and a sustained operational pulse can both be valuable without being interchangeable. 3. A worked example: voltage sag is not capacity Consider a hypothetical discharge test, not a specification for any commercial cell. Immediately before the pulse, current is zero and terminal voltage is 3.30 V. At a defined sampling point during a 100 A discharge pulse, voltage is 3.20 V. The effective resistance at that sampling point is 0.10 V divided by 100 A, or 0.001 ohm: 1 milliohm. Suppose the voltage instead reaches 3.15 V at a later sampling point while current remains 100 A. Using the same pre-pulse baseline gives 1.5 milliohms. The calculation has changed because the observed voltage response evolved with time, not because the tester necessarily made an error. Report the sampling time with the result. Longer pulses also change charge state and temperature, which complicates interpretation. For a separate, deliberately simplified fixed-resistance example, 100 A through 1 milliohm produces 0.10 V of drop and I²R loss of 10 W. Doubling the current to 200 A would produce 0.20 V of drop and 40 W of loss if resistance stayed constant. That square-law relationship explains why high-power operation can impose a disproportionate cooling burden. Do not mistake that simple resistor calculation for a complete battery thermal model. Reversible entropic heat, electrochemical polarization, changing temperature and other effects can matter. The Scientific Reports paper specifically discusses the limits of attributing all measured cell heat to Joule heating. A pulse-derived effective resistance is not automatically a complete heat-generation parameter. Nor does the 1 milliohm result reveal ampere-hour capacity. Capacity measures how much charge can be delivered under defined conditions; resistance characterizes a voltage-current response. A cell can lose usable capacity without a proportional increase in the resistance value selected for a particular test. A capacity test and a power test answer different acceptance questions. 4. The comparison must control the conditions Begin with temperature and state of charge. Both need a defined target and an agreed tolerance. Allow sufficient conditioning and rest under the chosen protocol; writing only “room temperature” can conceal meaningful differences. Record whether the value came from a cell, module or complete pack, because those are different measurement boundaries. Next specify the electrical stimulus. For DCIR, record the baseline current, pulse current, charge or discharge direction, pulse duration and sampling instants. For AC measurements, record frequency, signal amplitude and the quantity reported. For EIS, include the frequency range and the interpretation method. The raw voltage and current traces are often more informative than a single rounded result. Connections matter when the intended signal is very small. Lead and contact resistance can become a meaningful part of the measured path. The test report should state the connection and sensing arrangement and distinguish cell-terminal measurements from readings that include busbars, fuses or contactors. A pack-level number can be useful, but it cannot automatically be attributed to the cells alone. Compare new and aged cells under the same protocol before interpreting a trend. Track measurement uncertainty and repeatability as well as the average. A tiny apparent improvement is not commercially meaningful if it i