Relectrify: The Battery Controls Company Taking Inverterless Storage to Market
Relectrify turns cell-level control into an AC battery product. ARENA-backed deployments will test whether the architecture delivers bankable lifetime value.
Relectrify is making a different kind of battery-company bet. Rather than asking customers to adopt a new storage chemistry, the Melbourne-based business is changing how battery cells are controlled and how their electricity reaches an AC load. Its AC1 product combines cell-level management with power conversion, eliminating the separate inverter used in a conventional system architecture. That makes Relectrify a controls-and-power-electronics company as much as a storage supplier. The commercial question is not simply whether a battery cabinet works. It is whether thousands of individually controlled cells can deliver more usable energy, lower maintenance costs and credible long-term guarantees at a price customers will finance. An Australian Renewable Energy Agency-backed rollout provides a structured way to gather that evidence, but its deployment target should not be confused with an already operating fleet. Battery development work pictured on Relectrify’s company page. Credit: Relectrify. Hero: company-supplied AC1 product visualization, not an operating-site photograph. From second-life batteries to a control platform ARENA’s account of Relectrify’s development begins with work on reusing electric-vehicle batteries. The agency’s second-life trial page says the company developed a 36 kW / 120 kWh modular product using second-life Nissan Leaf battery packs, undertook certification testing, and manufactured and sold 15 units. That is a specific historical deployment record, not a statement about current AC1 production volume. The earlier work is relevant because reused cells create an unusually clear control problem: their condition and available capacity can differ. Managing a pack only as a collective unit can leave usable energy inaccessible when the limiting cell reaches its operating boundary. Individual control seeks to make the system less dependent on that weakest element, while respecting the limits of each cell. ARENA’s later funding announcement explicitly says the earlier project faced challenges. It describes the resulting advance as battery-management technology with broader potential, rather than presenting the second-life effort as a flawless straight-line success. That history is useful for readers evaluating deep technology: the durable asset can be the control architecture discovered through a difficult product development program. Relectrify now calls its platform CellSwitch. The company page identifies Jeff Renaud as chief executive, Niall Mai as chief technology officer and Ben Shepherd as chief product officer. Its patent-marking page lists AC1 and ReVolve among covered products and includes families relating to battery systems, reconfigurable management, fault handling and electronics assemblies. Patent coverage is evidence of an intellectual-property strategy, not independent proof of superior economics. What inverterless actually means In a conventional battery energy storage system, cells supply direct current and a power conversion system produces grid-compatible alternating current. ARENA’s More Energy Project description says Relectrify instead uses cell-level semiconductor circuitry operating at high frequency to produce an AC waveform directly. The separate inverter is removed from the system design, but power electronics and their engineering responsibilities do not disappear. That distinction prevents a misleading reading of the term inverterless. AC1 still has to manage switching, protection, electrical quality, thermal behavior and compliance. Its architectural difference is where and how those functions are implemented. Moving control closer to individual cells creates more granular information and flexibility, while also making electronics, firmware and system integration central to the product. Relectrify’s current US-facing product page describes AC1 as a 250 kW / 1 MWh modular battery with nearly 4,000 individually monitored and controlled cells. Those rounded figures imply approximately four hours of nominal energy at rated power. They are a product-page description, not a guarantee of four hours of usable AC output under every operating condition, and not a substitute for the applicable regional datasheet. The company says anomalous cells can be bypassed, energy can be balanced across cells and packs, and state of health can be monitored at cell level. These capabilities target real operating problems: stranded capacity, uneven aging and fault diagnosis. But bypassing a cell does not make its missing energy free, and no control system eliminates the need to assess safety at the complete installation level. ARENA is funding evidence, not certifying every claim ARENA announced A$25 million of support in 2025 to accelerate AC1 commercialization. Its stated deployment scope is up to 100 MWh in commercial and industrial applications and smaller front-of-meter projects. The agency’s project page repeats that cumulative nameplate target and says field performance data should build market confidence in the technology. The wording is important. Up to 100 MWh is a program objective, not a verified installed total as of November 17, 2026. Funding support is not customer revenue, and a demonstration portfolio is not the same thing as an independently measured long-term operating record. This profile does not infer completed deployments from a grant announcement. The program nevertheless has a clear commercial purpose. Prospective customers need reference installations, performance data and credible accounts of maintenance before committing to an unfamiliar architecture. Demonstrations across multiple sites can expose installation differences and operating conditions that a laboratory campaign cannot fully reproduce. ARENA also expects knowledge sharing through case studies and performance information. The agency identifies potential capital savings from removing the separate inverter, improved lifetime usable capacity through individual cell management, and operating savings from identifying and replacing faulty cells more precisely. These are the value hypotheses the rollout needs to test. They are not interchangeable with a published, all-in levelized storage cost applicable to every tariff, duty cycle or project size. Read the performance numbers carefully Relectrify’s product page makes several strong claims: 20-year performance guarantees, retention of 40% more original capacity after 20 years of daily cycling, delivery of 99% of available energy per cycle, and state-of-charge measurement with 99% accuracy. Each describes a different quantity. None should be casually rewritten as 99% round-trip efficiency. Round-trip efficiency compares energy returned with energy used to charge a system, using a defined measurement boundary. Available-energy utilization concerns how much accessible energy is delivered from the battery. State-of-charge accuracy concerns estimation. Capacity retention concerns aging. A buyer who mixes those measures can materially misjudge operating costs or lifetime output. ARENA’s 2025 release says the design can deliver 20% more energy over its lifetime. That is not necessarily inconsistent with the company’s later 40% capacity-retention comparison: cumulative lifetime throughput and end-of-period retained capacity are different metrics. Neither figure is useful as a universal project assumption without the comparison system, cycling regime and warranty conditions. The practical diligence questions are straightforward. What energy is guaranteed at the AC connection point? Under which temperature range and dispatch pattern? Who pays for replacement parts and field labor? What happens if the system is cycled more often than the reference case? How are downtime, degradation and auxiliary consumption measured? A well-specified contract matters more than a headline percentage. The public sources reviewed do not establish an independently audited fleet-wide availability number or a complete long-